España Hola! Bienvenido a visitar Шэньчжэньская микроэлектронная компания Хунтай !

Carrito de compras

Proyecto (S)
Photo Mfr. Part # Stock Quantity Datasheet Packaging Series ProductStatus MountingType CoilVoltage ContactForm ContactRating(Current) SwitchingVoltage CoilCurrent CoilType Features TerminationStyle SealRating CoilInsulation MustOperateVoltage MustReleaseVoltage OperateTime ReleaseTime OperatingTemperature ContactMaterial
MKS2XTIN-11 AC220

MKS2XTIN-11 AC220

RELAY GEN PURPOSE DPST 5A 220V

Omron Automation and Safety

3141
- +

Añadir

Investigación

MKS2XTIN-11 AC220

Datasheet

Bulk MKS-X Obsolete Socketable 220VAC DPST-NO/NC (1 Form A, 1 Form B) 5 A 220VDC - Max 10.5 mA Non Latching Lighted Indicator, Test Button Plug In - - 176 VAC 66 VAC 20 ms 20 ms -25°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS2XTIN-11 AC200

MKS2XTIN-11 AC200

RELAY GEN PURPOSE DPST 5A 200V

Omron Automation and Safety

3391
- +

Añadir

Investigación

MKS2XTIN-11 AC200

Datasheet

Bulk MKS-X Obsolete Socketable 200VAC DPST-NO/NC (1 Form A, 1 Form B) 5 A 220VDC - Max 11.6 mA Non Latching Lighted Indicator, Test Button Plug In - - 160 VAC 60 VAC 20 ms 20 ms -25°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS2XTIN-11 AC110

MKS2XTIN-11 AC110

RELAY GEN PURPOSE DPST 5A 110V

Omron Automation and Safety

3531
- +

Añadir

Investigación

MKS2XTIN-11 AC110

Datasheet

Bulk MKS-X Obsolete Socketable 110VAC DPST-NO/NC (1 Form A, 1 Form B) 5 A 220VDC - Max 21 mA Non Latching Lighted Indicator, Test Button Plug In - - 88 VAC 33 VAC 20 ms 20 ms -25°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS2XTIN-11 AC100

MKS2XTIN-11 AC100

RELAY GEN PURPOSE DPST 5A 100V

Omron Automation and Safety

3484
- +

Añadir

Investigación

MKS2XTIN-11 AC100

Datasheet

Bulk MKS-X Obsolete Socketable 100VAC DPST-NO/NC (1 Form A, 1 Form B) 5 A 220VDC - Max 23.1 mA Non Latching Lighted Indicator, Test Button Plug In - - 80 VAC 30 VAC 20 ms 20 ms -25°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS2XT-11 AC230

MKS2XT-11 AC230

RELAY GEN PURPOSE DPST 5A 230V

Omron Automation and Safety

2826
- +

Añadir

Investigación

MKS2XT-11 AC230

Datasheet

Bulk MKS-X Obsolete Socketable 230VAC DPST-NO/NC (1 Form A, 1 Form B) 5 A 220VDC - Max 10 mA Non Latching - Plug In - - 184 VAC 69 VAC 20 ms 20 ms -40°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS2XT-11 AC220

MKS2XT-11 AC220

RELAY GEN PURPOSE DPST 5A 220V

Omron Automation and Safety

3679
- +

Añadir

Investigación

MKS2XT-11 AC220

Datasheet

Bulk MKS-X Obsolete Socketable 220VAC DPST-NO/NC (1 Form A, 1 Form B) 5 A 220VDC - Max 10.5 mA Non Latching - Plug In - - 176 VAC 66 VAC 20 ms 20 ms -40°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS2XT-11 AC200

MKS2XT-11 AC200

RELAY GEN PURPOSE DPST 5A 200V

Omron Automation and Safety

3915
- +

Añadir

Investigación

MKS2XT-11 AC200

Datasheet

Bulk MKS-X Obsolete Socketable 200VAC DPST-NO/NC (1 Form A, 1 Form B) 5 A 220VDC - Max 11.6 mA Non Latching - Plug In - - 160 VAC 60 VAC 20 ms 20 ms -40°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS2XT-11 AC100

MKS2XT-11 AC100

RELAY GEN PURPOSE DPST 5A 100V

Omron Automation and Safety

2541
- +

Añadir

Investigación

MKS2XT-11 AC100

Datasheet

Bulk MKS-X Obsolete Socketable 100VAC DPST-NO/NC (1 Form A, 1 Form B) 5 A 220VDC - Max 23.1 mA Non Latching - Plug In - - 80 VAC 30 VAC 20 ms 20 ms -40°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS1XTIN-10 DC110

MKS1XTIN-10 DC110

RELAY GEN PURPOSE SPST 10A 110V

Omron Automation and Safety

2958
- +

Añadir

Investigación

MKS1XTIN-10 DC110

Datasheet

Bulk MKS-X Obsolete Socketable 110VDC SPST-NO (1 Form A) 10 A 220VDC - Max 13.6 mA Non Latching Lighted Indicator, Test Button Plug In - - 88 VDC 16.5 VDC 30 ms 20 ms -25°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS1XTIN-10 AC230

MKS1XTIN-10 AC230

RELAY GEN PURPOSE SPST 10A 230V

Omron Automation and Safety

3168
- +

Añadir

Investigación

MKS1XTIN-10 AC230

Datasheet

Bulk MKS-X Obsolete Socketable 230VAC SPST-NO (1 Form A) 10 A 220VDC - Max 10 mA Non Latching Lighted Indicator, Test Button Plug In - - 184 VAC 69 VAC 20 ms 20 ms -25°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS1XTIN-10 AC200

MKS1XTIN-10 AC200

RELAY GEN PURPOSE SPST 10A 200V

Omron Automation and Safety

2966
- +

Añadir

Investigación

MKS1XTIN-10 AC200

Datasheet

Bulk MKS-X Obsolete Socketable 200VAC SPST-NO (1 Form A) 10 A 220VDC - Max 11.6 mA Non Latching Lighted Indicator, Test Button Plug In - - 160 VAC 60 VAC 20 ms 20 ms -25°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS1XTIN-10 AC100

MKS1XTIN-10 AC100

RELAY GEN PURPOSE SPST 10A 100V

Omron Automation and Safety

3325
- +

Añadir

Investigación

MKS1XTIN-10 AC100

Datasheet

Bulk MKS-X Obsolete Socketable 100VAC SPST-NO (1 Form A) 10 A 220VDC - Max 23.1 mA Non Latching Lighted Indicator, Test Button Plug In - - 80 VAC 30 VAC 20 ms 20 ms -25°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS1XTN-10 AC230

MKS1XTN-10 AC230

RELAY GEN PURPOSE SPST 10A 230V

Omron Automation and Safety

3726
- +

Añadir

Investigación

MKS1XTN-10 AC230

Datasheet

Bulk MKS-X Obsolete Socketable 230VAC SPST-NO (1 Form A) 10 A 220VDC - Max 10 mA Non Latching Lighted Indicator Plug In - - 184 VAC 69 VAC 20 ms 20 ms -25°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS1XTN-10 AC220

MKS1XTN-10 AC220

RELAY GEN PURPOSE SPST 10A 220V

Omron Automation and Safety

2656
- +

Añadir

Investigación

MKS1XTN-10 AC220

Datasheet

Bulk MKS-X Obsolete Socketable 220VAC SPST-NO (1 Form A) 10 A 220VDC - Max 10.5 mA Non Latching Lighted Indicator Plug In - - 176 VAC 66 VAC 20 ms 20 ms -25°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS1XTN-10 AC200

MKS1XTN-10 AC200

RELAY GEN PURPOSE SPST 10A 200V

Omron Automation and Safety

2100
- +

Añadir

Investigación

MKS1XTN-10 AC200

Datasheet

Bulk MKS-X Obsolete Socketable 200VAC SPST-NO (1 Form A) 10 A 220VDC - Max 11.6 mA Non Latching Lighted Indicator Plug In - - 160 VAC 60 VAC 20 ms 20 ms -25°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS1XTN-10 AC100

MKS1XTN-10 AC100

RELAY GEN PURPOSE SPST 10A 100V

Omron Automation and Safety

2535
- +

Añadir

Investigación

MKS1XTN-10 AC100

Datasheet

Bulk MKS-X Obsolete Socketable 100VAC SPST-NO (1 Form A) 10 A 220VDC - Max 23.1 mA Non Latching Lighted Indicator Plug In - - 80 VAC 30 VAC 20 ms 20 ms -25°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS1XT-10 AC230

MKS1XT-10 AC230

RELAY GEN PURPOSE SPST 10A 230V

Omron Automation and Safety

2373
- +

Añadir

Investigación

MKS1XT-10 AC230

Datasheet

Bulk MKS-X Obsolete Socketable 230VAC SPST-NO (1 Form A) 10 A 220VDC - Max 10 mA Non Latching - Plug In - - 184 VAC 69 VAC 20 ms 20 ms -40°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS1XT-10 AC220

MKS1XT-10 AC220

RELAY GEN PURPOSE SPST 10A 220V

Omron Automation and Safety

2262
- +

Añadir

Investigación

MKS1XT-10 AC220

Datasheet

Bulk MKS-X Obsolete Socketable 220VAC SPST-NO (1 Form A) 10 A 220VDC - Max 10.5 mA Non Latching - Plug In - - 176 VAC 66 VAC 20 ms 20 ms -40°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS1XT-10 AC200

MKS1XT-10 AC200

RELAY GEN PURPOSE SPST 10A 200V

Omron Automation and Safety

2189
- +

Añadir

Investigación

MKS1XT-10 AC200

Datasheet

Bulk MKS-X Obsolete Socketable 200VAC SPST-NO (1 Form A) 10 A 220VDC - Max 11.6 mA Non Latching - Plug In - - 160 VAC 60 VAC 20 ms 20 ms -40°C ~ 60°C Silver Tin Indium (AgSnIn)
MKS1XT-10 AC100

MKS1XT-10 AC100

RELAY GEN PURPOSE SPST 10A 100V

Omron Automation and Safety

2162
- +

Añadir

Investigación

MKS1XT-10 AC100

Datasheet

Bulk MKS-X Obsolete Socketable 100VAC SPST-NO (1 Form A) 10 A 220VDC - Max 23.1 mA Non Latching - Plug In - - 80 VAC 30 VAC 20 ms 20 ms -40°C ~ 60°C Silver Tin Indium (AgSnIn)
Total 23635 Records«Prev1... 883884885886887888889890...1182Next»
Solicitud de cotización
Número de pieza
Cantidad
Contacto
Correo electrónico
Empresa
Comentarios